HIMEL HDB9H63A2C16 Miniature Circuit Breaker (MCB) 2P 16A 10kA Type C
The HIMEL HDB9H63A2C16 Miniature Circuit Breaker (MCB) is designed to provide reliable protection against overloads and short circuits in low-voltage electrical systems. Featuring a 2 Pole (2P) configuration, a 16A rated current, and a 10kA breaking capacity, it delivers dependable protection for residential, commercial, and industrial electrical installations.
Equipped with a Type C tripping curve, high interrupting capacity, and DIN rail mounting, the HDB9H63A2C16 ensures safe circuit isolation while complying with the EN/IEC 60898-1 international standard.
HIMEL HDB9H63A2C16 Miniature Circuit Breaker (MCB) 2P 16A 10kA Type C Key Features
- 2 Pole (2P) Miniature Circuit Breaker (MCB)
- 16A Rated Current
- 10kA Breaking Capacity
- Type C Tripping Curve
- 230V AC Rated Voltage
- Overload Protection
- Short Circuit Protection
- 35 mm DIN Rail Mounting
- 20,000 Mechanical Operations
- 10,000 Electrical Operations
- Limitation Class 3
- Certified to EN/IEC 60898-1
HIMEL HDB9H63A2C16 Miniature Circuit Breaker (MCB) 2P 16A 10kA Type C Applications
- Residential Distribution Boards
- Commercial Electrical Systems
- Industrial Control Panels
- Power Distribution Circuits
- Lighting Circuits
- Socket Outlet Protection
- Electrical Maintenance Projects
- Low Voltage Protection Systems
HIMEL HDB9H63A2C16 Miniature Circuit Breaker (MCB) 2P 16A 10kA Type C Technical Specifications
| Brand | HIMEL |
| Series | HDB9 |
| Model | HDB9H63A2C16 |
| Product Type | Miniature Circuit Breaker (MCB) |
| Pole Configuration | 2 Pole (2P) |
| Rated Current | 16A |
| Rated Voltage | 230V AC |
| Breaking Capacity | 10kA |
| Tripping Curve | Type C |
| Frequency | 50/60Hz |
| Mounting | 35 mm DIN Rail |
| Mechanical Durability | 20,000 Cycles |
| Electrical Durability | 10,000 Cycles |
| Insulation Voltage | 500V |
| Standard | EN/IEC 60898-1 |
| Certifications | KEMA, CB, CE |
HIMEL HDB9H63A2C16 Miniature Circuit Breaker (MCB) 2P 16A 10kA Type C FAQ
What is the HDB9H63A2C16 used for?
It protects electrical circuits against overloads and short circuits in residential, commercial, and industrial applications.
What does the Type C tripping curve mean?
Type C breakers are suitable for circuits with moderate inrush currents such as lighting systems, socket outlets, and small motors.
How is the breaker installed?
The breaker mounts easily on a standard 35 mm DIN rail inside distribution boards and control panels.
Does it comply with international standards?
Yes. It complies with EN/IEC 60898-1 and carries KEMA, CB, and CE certifications.
For complete technical specifications, visit the HIMEL Official Website .











Reviews
There are no reviews yet.