{"id":2489,"date":"2026-07-14T11:41:36","date_gmt":"2026-07-14T08:41:36","guid":{"rendered":"https:\/\/wordpress.gfmegypt.com\/?post_type=product&#038;p=2489"},"modified":"2026-08-29T21:40:20","modified_gmt":"2026-08-29T18:40:20","slug":"himel-molded-case-circuit-breaker-mccb-3p-100a-25ka-thermal-magnetic-hdm3100s10033xx","status":"publish","type":"product","link":"https:\/\/wordpress.gfmegypt.com\/ar\/product\/himel-molded-case-circuit-breaker-mccb-3p-100a-25ka-thermal-magnetic-hdm3100s10033xx\/","title":{"rendered":"HIMEL Molded Case Circuit Breaker (MCCB) 3P 100A 25kA Thermal-Magnetic \u2013 HDM3100S10033XX"},"content":{"rendered":"<p><strong>HIMEL Molded Case Circuit Breaker MCCB 3P 100A 25kA HDM3100S10033XX<\/strong><\/p>\n<h2>HIMEL Molded Case Circuit Breaker MCCB 3P 100A 25kA HDM3100S10033XX<\/h2>\n<p>\u0625\u0646 <strong>HIMEL HDM3100S10033XX Molded Case Circuit Breaker (MCCB)<\/strong> is engineered to provide reliable overload and short-circuit protection for low-voltage power distribution systems. Featuring a <strong>\u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0642\u0637\u0627\u0628 (3P)<\/strong> design, <strong>100A rated current<\/strong>, <strong>25kA breaking capacity<\/strong>, and <strong>18kA service breaking capacity (Ics)<\/strong>, this MCCB delivers dependable performance in demanding commercial and industrial environments.<\/p>\n<p>Equipped with a <strong>thermal-magnetic trip unit<\/strong>, <strong>100AF frame size<\/strong>, and <strong>fixed front mounting<\/strong>, the HDM3100S10033XX complies with <strong>IEC 60947-2<\/strong> and provides long-lasting protection for electrical distribution panels and machinery.<\/p>\n<h3>HIMEL Molded Case Circuit Breaker MCCB 3P 100A 25kA HDM3100S10033XX Key Features<\/h3>\n<ul>\n<li>3 Pole (3P) Molded Case Circuit Breaker<\/li>\n<li>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646: 100 \u0623\u0645\u0628\u064a\u0631<\/li>\n<li>25kA Breaking Capacity<\/li>\n<li>18kA Service Breaking Capacity (Ics)<\/li>\n<li>100AF Frame Size<\/li>\n<li>Thermal-Magnetic Trip Unit<\/li>\n<li>400\/415V AC Rated Voltage<\/li>\n<li>800V Rated Insulation Voltage<\/li>\n<li>Fixed Front Mounting<\/li>\n<li>\u062d\u0645\u0627\u064a\u0629 \u0636\u062f \u0627\u0644\u0623\u062d\u0645\u0627\u0644 \u0627\u0644\u0632\u0627\u0626\u062f\u0629<\/li>\n<li>\u062d\u0645\u0627\u064a\u0629 \u0636\u062f \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0642\u0635\u064a\u0631\u0629<\/li>\n<li>\u0645\u0642\u0628\u0636 \u062a\u0634\u063a\u064a\u0644 \u0642\u0627\u0628\u0644 \u0644\u0644\u0642\u0641\u0644 \u0628\u0648\u0627\u0633\u0637\u0629 \u0642\u0641\u0644 \u0623\u0645\u0627\u0646 (Padlock)<\/li>\n<li>IEC 60947-2 Compliant<\/li>\n<li>CE &amp; T\u00dcV Certified<\/li>\n<\/ul>\n<h3>HDM3100S10033XX Applications<\/h3>\n<ul>\n<li>Main Power Distribution Panels<\/li>\n<li>Industrial Electrical Systems<\/li>\n<li>\u0627\u0644\u0645\u0628\u0627\u0646\u064a \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629<\/li>\n<li>\u062f\u0648\u0627\u0626\u0631 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a<\/li>\n<li>Manufacturing Facilities<\/li>\n<li>\u0644\u0648\u062d\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u0627\u0643\u064a\u0646\u0627\u062a<\/li>\n<li>\u0623\u0646\u0638\u0645\u0629 \u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636<\/li>\n<li>Infrastructure Projects<\/li>\n<\/ul>\n<h3>HDM3100S10033XX Technical Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<td><strong>\u0627\u0644\u0639\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629<\/strong><\/td>\n<td>\u0647\u064a\u0645\u064a\u0644 (HIMEL)<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u0633\u0644\u0633\u0644\u0629<\/strong><\/td>\n<td>HDM3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0631\u0642\u0645 \u0627\u0644\u0645\u0648\u062f\u064a\u0644<\/strong><\/td>\n<td>HDM3100S10033XX<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0646\u0648\u0639 \u0627\u0644\u0645\u0646\u062a\u062c<\/strong><\/td>\n<td>Molded Case Circuit Breaker (MCCB)<\/td>\n<\/tr>\n<tr>\n<td><strong>\u062a\u0643\u0648\u064a\u0646 \u0627\u0644\u0623\u0642\u0637\u0627\u0628<\/strong><\/td>\n<td>\u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0642\u0637\u0627\u0628 (3P)<\/td>\n<\/tr>\n<tr>\n<td><strong>Frame Size<\/strong><\/td>\n<td>100AF<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/strong><\/td>\n<td>100A<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/strong><\/td>\n<td>400\/415V AC<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u062a\u0631\u062f\u062f<\/strong><\/td>\n<td>50\/60 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0642\u062f\u0631\u0629 \u0627\u0644\u0642\u0637\u0639<\/strong><\/td>\n<td>25kA<\/td>\n<\/tr>\n<tr>\n<td><strong>Service Breaking Capacity (Ics)<\/strong><\/td>\n<td>18kA<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated Insulation Voltage<\/strong><\/td>\n<td>800V<\/td>\n<\/tr>\n<tr>\n<td><strong>Trip Unit Technology<\/strong><\/td>\n<td>\u062d\u0631\u0627\u0631\u064a-\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0646\u0648\u0639 \u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/strong><\/td>\n<td>Fixed Front<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/strong><\/td>\n<td>20,000 Cycles (with maintenance)<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/strong><\/td>\n<td>4,000 Cycles<\/td>\n<\/tr>\n<tr>\n<td><strong>\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/strong><\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u0645\u0639\u064a\u0627\u0631<\/strong><\/td>\n<td>IEC 60947-2<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u0634\u0647\u0627\u062f\u0627\u062a<\/strong><\/td>\n<td>CE, T\u00dcV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>HDM3100S10033XX FAQ<\/h3>\n<p><strong>What is the HDM3100S10033XX used for?<\/strong><br \/>\nIt protects commercial and industrial power distribution systems against overloads and short circuits.<\/p>\n<p><strong>What does the 25kA breaking capacity mean?<\/strong><br \/>\nIt indicates the maximum fault current the MCCB can safely interrupt without damage.<\/p>\n<p><strong>What is the difference between Breaking Capacity and Ics?<\/strong><br \/>\nBreaking Capacity is the maximum interrupting capability, while Ics (18kA) is the rated service breaking capacity for repeated operation.<\/p>\n<p><strong>Does this MCCB comply with international standards?<\/strong><br \/>\nYes. It complies with IEC 60947-2 and is certified by CE and T\u00dcV.<\/p>\n<p>\u0644\u0644\u0627\u0637\u0644\u0627\u0639 \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629 \u0627\u0644\u0643\u0627\u0645\u0644\u0629\u060c \u064a\u064f\u0631\u062c\u0649 \u0632\u064a\u0627\u0631\u0629 \u0627\u0644\u0645\u0648\u0642\u0639 \u0627\u0644\u0631\u0633\u0645\u064a \u0644\u0634\u0631\u0643\u0629 HIMEL.<br \/>\n<a href=\"https:\/\/www.himel.com\/gb\" target=\"_blank\" rel=\"noopener noreferrer\">\u0627\u0644\u0645\u0648\u0642\u0639 \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a \u0627\u0644\u0631\u0633\u0645\u064a \u0644\u0634\u0631\u0643\u0629 HIMEL<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0625\u0646 <strong data-start=\"152\" data-end=\"212\">HIMEL HDM3100S10033XX Molded Case Circuit Breaker (MCCB)<\/strong> features a <strong data-start=\"224\" data-end=\"239\">\u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0642\u0637\u0627\u0628 (3P)<\/strong> \u0627\u0644\u062a\u0647\u064a\u0626\u0629 <strong data-start=\"255\" data-end=\"277\">100A rated current<\/strong>, <strong data-start=\"279\" data-end=\"305\">25kA breaking capacity<\/strong>, and <strong data-start=\"311\" data-end=\"351\">18kA service breaking capacity (Ics)<\/strong>. Designed with a <strong data-start=\"369\" data-end=\"399\">thermal-magnetic trip unit<\/strong>, it provides dependable overload and short-circuit protection for commercial and industrial power distribution systems.<\/p>","protected":false},"featured_media":2493,"comment_status":"open","ping_status":"closed","template":"","meta":{"pagelayer_contact_templates":[],"_pagelayer_content":"","advanced_seo_description":"","jetpack_seo_html_title":"","jetpack_seo_noindex":false,"jetpack_seo_schema_type":""},"product_brand":[36],"product_cat":[58],"product_tag":[507,509,508,505,506,52,501,502,45,336,503,504,511,510],"class_list":["post-2489","product","type-product","status-publish","has-post-thumbnail","product_brand-himel","product_cat-molded-case-circuit-breakers-mccb","product_tag-100a-mccb","product_tag-18ka-ics","product_tag-25ka-mccb","product_tag-3-pole-mccb","product_tag-3p-mccb","product_tag-electrical-protection","product_tag-hdm3","product_tag-hdm3100s10033xx","product_tag-himel","product_tag-industrial-circuit-breaker","product_tag-mccb","product_tag-molded-case-circuit-breaker","product_tag-power-distribution","product_tag-thermal-magnetic-mccb","first","instock","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product\/2489","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/comments?post=2489"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/media\/2493"}],"wp:attachment":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/media?parent=2489"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product_brand?post=2489"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product_cat?post=2489"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product_tag?post=2489"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}