{"id":2516,"date":"2026-07-14T13:51:34","date_gmt":"2026-07-14T10:51:34","guid":{"rendered":"https:\/\/wordpress.gfmegypt.com\/?post_type=product&#038;p=2516"},"modified":"2026-08-29T21:40:20","modified_gmt":"2026-08-29T18:40:20","slug":"himel-molded-case-circuit-breaker-mccb-3p-125a-35ka-thermal-magnetic-hdm3160s12533xx","status":"publish","type":"product","link":"https:\/\/wordpress.gfmegypt.com\/ar\/product\/himel-molded-case-circuit-breaker-mccb-3p-125a-35ka-thermal-magnetic-hdm3160s12533xx\/","title":{"rendered":"HIMEL Molded Case Circuit Breaker (MCCB) 3P 125A 35kA Thermal-Magnetic HDM3160S12533XX"},"content":{"rendered":"<p><strong>HIMEL Molded Case Circuit Breaker (MCCB) 3P 125A 35kA Thermal-Magnetic HDM3160S12533XX<\/strong> is designed for reliable industrial power distribution and circuit protection.<\/p>\n<h2>HIMEL Molded Case Circuit Breaker (MCCB) 3P 125A 35kA Thermal-Magnetic HDM3160S12533XX<\/h2>\n<p>\n\u0625\u0646 <strong>HIMEL HDM3160S12533XX Molded Case Circuit Breaker (MCCB)<\/strong> is designed to provide dependable overload and short-circuit protection for commercial and industrial electrical distribution systems. Featuring a <strong>\u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0642\u0637\u0627\u0628 (3P)<\/strong> \u0627\u0644\u062a\u0647\u064a\u0626\u0629 <strong>125A rated current<\/strong>, <strong>35kA breaking capacity<\/strong>\u060c \u0628\u0627\u0644\u0625\u0636\u0627\u0641\u0629 \u0625\u0644\u0649 <strong>160AF frame size<\/strong>, it delivers reliable protection for demanding power distribution applications.\n<\/p>\n<p>\nEquipped with a <strong>thermal-magnetic trip unit<\/strong>, <strong>400\/415V AC operating voltage<\/strong>, <strong>21kA service breaking capacity (Ics)<\/strong>, and fixed front mounting, the HDM3160S12533XX complies with <strong>IEC 60947-2<\/strong> and ensures long-term operational reliability.\n<\/p>\n<h3>HIMEL Molded Case Circuit Breaker (MCCB) 3P 125A 35kA Thermal-Magnetic HDM3160S12533XX Key Features<\/h3>\n<ul>\n<li>3 Pole (3P) Molded Case Circuit Breaker (MCCB)<\/li>\n<li>\u062a\u064a\u0627\u0631 \u0645\u0642\u0646\u0646 125 \u0623\u0645\u0628\u064a\u0631<\/li>\n<li>35kA Breaking Capacity (Icu)<\/li>\n<li>21kA Service Breaking Capacity (Ics)<\/li>\n<li>160AF Frame Size<\/li>\n<li>Thermal-Magnetic Trip Unit<\/li>\n<li>400\/415V AC Rated Voltage<\/li>\n<li>800V Rated Insulation Voltage<\/li>\n<li>50\/60Hz Operation<\/li>\n<li>Fixed Front Mounting<\/li>\n<li>\u062d\u0645\u0627\u064a\u0629 \u0636\u062f \u0627\u0644\u0623\u062d\u0645\u0627\u0644 \u0627\u0644\u0632\u0627\u0626\u062f\u0629<\/li>\n<li>\u062d\u0645\u0627\u064a\u0629 \u0636\u062f \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0642\u0635\u064a\u0631\u0629<\/li>\n<li>\u0645\u0642\u0628\u0636 \u0642\u0627\u0628\u0644 \u0644\u0644\u0642\u0641\u0644 \u0628\u0642\u0641\u0644 \u0623\u0645\u0627\u0646<\/li>\n<li>IEC 60947-2 Certified<\/li>\n<li>CE &amp; KEMA Certified<\/li>\n<\/ul>\n<h3>HIMEL Molded Case Circuit Breaker (MCCB) 3P 125A 35kA Thermal-Magnetic HDM3160S12533XX Applications<\/h3>\n<ul>\n<li>Main Power Distribution Panels<\/li>\n<li>Industrial Switchboards<\/li>\n<li>\u0627\u0644\u0645\u0628\u0627\u0646\u064a \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629<\/li>\n<li>Electrical Distribution Systems<\/li>\n<li>\u062f\u0648\u0627\u0626\u0631 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a<\/li>\n<li>Manufacturing Facilities<\/li>\n<li>Power Control Panels<\/li>\n<li>\u0627\u0644\u0622\u0644\u0627\u062a \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629<\/li>\n<\/ul>\n<h3>HIMEL Molded Case Circuit Breaker (MCCB) 3P 125A 35kA Thermal-Magnetic HDM3160S12533XX Technical Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<td><strong>\u0627\u0644\u0639\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629<\/strong><\/td>\n<td>\u0647\u064a\u0645\u064a\u0644 (HIMEL)<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u0633\u0644\u0633\u0644\u0629<\/strong><\/td>\n<td>HDM3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0631\u0642\u0645 \u0627\u0644\u0645\u0648\u062f\u064a\u0644<\/strong><\/td>\n<td>HDM3160S12533XX<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0646\u0648\u0639 \u0627\u0644\u0645\u0646\u062a\u062c<\/strong><\/td>\n<td>Molded Case Circuit Breaker (MCCB)<\/td>\n<\/tr>\n<tr>\n<td><strong>\u062a\u0643\u0648\u064a\u0646 \u0627\u0644\u0623\u0642\u0637\u0627\u0628<\/strong><\/td>\n<td>\u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0642\u0637\u0627\u0628 (3P)<\/td>\n<\/tr>\n<tr>\n<td><strong>Frame Size<\/strong><\/td>\n<td>160AF<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/strong><\/td>\n<td>125A<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/strong><\/td>\n<td>400\/415V AC<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u062a\u0631\u062f\u062f<\/strong><\/td>\n<td>50\/60 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td><strong>Breaking Capacity (Icu)<\/strong><\/td>\n<td>35kA<\/td>\n<\/tr>\n<tr>\n<td><strong>Service Breaking Capacity (Ics)<\/strong><\/td>\n<td>21kA<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated Insulation Voltage<\/strong><\/td>\n<td>800V<\/td>\n<\/tr>\n<tr>\n<td><strong>Trip Unit Technology<\/strong><\/td>\n<td>\u062d\u0631\u0627\u0631\u064a-\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0646\u0648\u0639 \u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/strong><\/td>\n<td>Fixed Front<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/strong><\/td>\n<td>20,000 Cycles (with maintenance)<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/strong><\/td>\n<td>4,000 Cycles<\/td>\n<\/tr>\n<tr>\n<td><strong>\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/strong><\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u0645\u0639\u064a\u0627\u0631<\/strong><\/td>\n<td>IEC 60947-2<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0627\u0644\u0634\u0647\u0627\u062f\u0627\u062a<\/strong><\/td>\n<td>CE, KEMA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>HIMEL Molded Case Circuit Breaker (MCCB) 3P 125A 35kA Thermal-Magnetic HDM3160S12533XX FAQ<\/h3>\n<p><strong>What is the HDM3160S12533XX used for?<\/strong><br \/>\nIt protects industrial and commercial electrical systems against overloads and short circuits.<\/p>\n<p><strong>What type of trip unit does it use?<\/strong><br \/>\nIt features a thermal-magnetic trip unit for dependable protection.<\/p>\n<p><strong>What is the frame size?<\/strong><br \/>\nThis MCCB is built on a 160AF frame.<\/p>\n<p><strong>Which standard does it comply with?<\/strong><br \/>\nIt complies with IEC 60947-2 and carries CE and KEMA certifications.<\/p>\n<p>\u0644\u0644\u0627\u0637\u0644\u0627\u0639 \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629 \u0627\u0644\u0643\u0627\u0645\u0644\u0629\u060c \u064a\u064f\u0631\u062c\u0649 \u0632\u064a\u0627\u0631\u0629 \u0627\u0644\u0645\u0648\u0642\u0639 \u0627\u0644\u0631\u0633\u0645\u064a \u0644\u0634\u0631\u0643\u0629 HIMEL. <a href=\"https:\/\/www.himel.com\/gb\" target=\"_blank\" rel=\"noopener\">\u0627\u0644\u0645\u0648\u0642\u0639 \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a \u0627\u0644\u0631\u0633\u0645\u064a \u0644\u0634\u0631\u0643\u0629 HIMEL<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0625\u0646 <strong data-start=\"151\" data-end=\"211\">HIMEL HDM3160S12533XX Molded Case Circuit Breaker (MCCB)<\/strong> features a <strong data-start=\"223\" data-end=\"238\">\u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0642\u0637\u0627\u0628 (3P)<\/strong> design with <strong data-start=\"251\" data-end=\"273\">125A rated current<\/strong>, <strong data-start=\"275\" data-end=\"301\">35kA breaking capacity<\/strong>, <strong data-start=\"303\" data-end=\"343\">21kA service breaking capacity (Ics)<\/strong>, <strong data-start=\"345\" data-end=\"365\">160AF frame size<\/strong>\u060c \u0628\u0627\u0644\u0625\u0636\u0627\u0641\u0629 \u0625\u0644\u0649 <strong data-start=\"373\" data-end=\"403\">thermal-magnetic trip unit<\/strong>. Designed for reliable overload and short-circuit protection in industrial and commercial power distribution systems.<\/p>","protected":false},"featured_media":2520,"comment_status":"open","ping_status":"closed","template":"","meta":{"pagelayer_contact_templates":[],"_pagelayer_content":"","advanced_seo_description":"","jetpack_seo_html_title":"","jetpack_seo_noindex":false,"jetpack_seo_schema_type":""},"product_brand":[36],"product_cat":[58],"product_tag":[516,518,505,517,506,52,501,520,45,336,503,504,511,510],"class_list":["post-2516","product","type-product","status-publish","has-post-thumbnail","product_brand-himel","product_cat-molded-case-circuit-breakers-mccb","product_tag-125a-mccb","product_tag-160af-mccb","product_tag-3-pole-mccb","product_tag-35ka-mccb","product_tag-3p-mccb","product_tag-electrical-protection","product_tag-hdm3","product_tag-hdm3160s12533xx","product_tag-himel","product_tag-industrial-circuit-breaker","product_tag-mccb","product_tag-molded-case-circuit-breaker","product_tag-power-distribution","product_tag-thermal-magnetic-mccb","first","instock","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product\/2516","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/comments?post=2516"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/media\/2520"}],"wp:attachment":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/media?parent=2516"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product_brand?post=2516"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product_cat?post=2516"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product_tag?post=2516"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}