{"id":2569,"date":"2026-07-14T16:57:57","date_gmt":"2026-07-14T13:57:57","guid":{"rendered":"https:\/\/wordpress.gfmegypt.com\/?post_type=product&#038;p=2569"},"modified":"2026-08-29T21:40:21","modified_gmt":"2026-08-29T18:40:21","slug":"himel-molded-case-circuit-breaker-mccb-3p-40a-35ka-thermal-magnetic-hdm3s160m04031xx","status":"publish","type":"product","link":"https:\/\/wordpress.gfmegypt.com\/ar\/product\/himel-molded-case-circuit-breaker-mccb-3p-40a-35ka-thermal-magnetic-hdm3s160m04031xx\/","title":{"rendered":"HIMEL Molded Case Circuit Breaker (MCCB) 3P 40A 35kA Thermal-Magnetic HDM3S160M04031XX"},"content":{"rendered":"<p><strong>Reliable Thermal-Magnetic Protection for Industrial and Commercial Power Distribution<\/strong><\/p>\n<p>\n\u0625\u0646 <strong>HIMEL Molded Case Circuit Breaker (MCCB) 3P 40A 35kA Thermal-Magnetic HDM3S160M04031XX<\/strong> is designed to provide dependable protection against overloads and short circuits in low-voltage AC power distribution systems. Equipped with a thermal-magnetic trip unit, it ensures reliable operation while protecting electrical equipment from fault conditions.\n<\/p>\n<h2>HIMEL Molded Case Circuit Breaker (MCCB) 3P 40A 35kA Thermal-Magnetic HDM3S160M04031XX<\/h2>\n<p>\nDesigned for industrial and commercial applications, this HIMEL MCCB combines a 40A current rating with a 35kA breaking capacity to provide reliable circuit protection. Its enclosed molded case construction enhances durability while maintaining dependable performance in demanding electrical environments.\n<\/p>\n<p>\nThe breaker operates on 400\/415V AC systems at 50\/60Hz and features a 3-pole configuration with thermal-magnetic trip technology. It is suitable for isolation and complies with IEC 60947-2, making it an excellent choice for power distribution protection.\n<\/p>\n<h3>HIMEL Molded Case Circuit Breaker (MCCB) 3P 40A 35kA Thermal-Magnetic HDM3S160M04031XX Key Features<\/h3>\n<ul>\n<li>Brand: HIMEL<\/li>\n<li>Product Type: Enclosed Molded Case Circuit Breaker (MCCB)<\/li>\n<li>Series: HDM3S<\/li>\n<li>Model: HDM3S160M04031XX<\/li>\n<li>Frame Size: 160AF<\/li>\n<li>Current Rating: 40A<\/li>\n<li>Pole Configuration: 3P<\/li>\n<li>Rated Breaking Capacity: 35kA at 400V<\/li>\n<li>Service Breaking Capacity (Ics): 35kA at 400V<\/li>\n<li>Trip Unit Technology: Thermal-Magnetic<\/li>\n<li>Rated Operational Voltage: 400\/415V AC<\/li>\n<li>Rated Insulation Voltage: 1000V<\/li>\n<li>Rated Impulse Withstand Voltage: 8kV<\/li>\n<li>Frequency: 50\/60Hz<\/li>\n<li>Suitable for Isolation: Yes<\/li>\n<li>Application: Power Distribution Protection<\/li>\n<li>Electrical Durability: 1,500 Cycles<\/li>\n<li>Mechanical Durability: 8,500 Cycles<\/li>\n<li>Connection Capacity: 70 mm\u00b2<\/li>\n<li>Utilisation Category: Category A<\/li>\n<li>Protection Degree: IP20<\/li>\n<li>Operating Temperature: -5\u00b0C to +40\u00b0C<\/li>\n<li>Storage Temperature: -20\u00b0C to +70\u00b0C<\/li>\n<li>Operating Altitude: 0\u20132000 m<\/li>\n<li>Standard: IEC 60947-2<\/li>\n<li>Certification: T\u00dcV<\/li>\n<\/ul>\n<h3>HIMEL MCCB 3P 40A HDM3S160M04031XX Applications<\/h3>\n<ul>\n<li>Industrial power distribution systems<\/li>\n<li>Commercial electrical installations<\/li>\n<li>Main distribution boards<\/li>\n<li>Sub-distribution panels<\/li>\n<li>Motor protection circuits<\/li>\n<li>Feeder protection applications<\/li>\n<li>Manufacturing facilities<\/li>\n<li>Infrastructure and utility projects<\/li>\n<li>Low-voltage switchboards<\/li>\n<li>Electrical control panels<\/li>\n<\/ul>\n<h3>HIMEL MCCB 3P 40A 35kA HDM3S160M04031XX Technical Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Value<\/th>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0639\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629<\/td>\n<td>\u0647\u064a\u0645\u064a\u0644 (HIMEL)<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0633\u0644\u0633\u0644\u0629<\/td>\n<td>HDM3S<\/td>\n<\/tr>\n<tr>\n<td>\u0631\u0642\u0645 \u0627\u0644\u0645\u0648\u062f\u064a\u0644<\/td>\n<td>HDM3S160M04031XX<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0648\u0639 \u0627\u0644\u0645\u0646\u062a\u062c<\/td>\n<td>Enclosed Molded Case Circuit Breaker (MCCB)<\/td>\n<\/tr>\n<tr>\n<td>Frame Size<\/td>\n<td>160AF<\/td>\n<\/tr>\n<tr>\n<td>Current Rating<\/td>\n<td>40A<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0643\u0648\u064a\u0646 \u0627\u0644\u0623\u0642\u0637\u0627\u0628<\/td>\n<td>3P<\/td>\n<\/tr>\n<tr>\n<td>Trip Unit Technology<\/td>\n<td>\u062d\u0631\u0627\u0631\u064a-\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a<\/td>\n<\/tr>\n<tr>\n<td>Rated Operational Voltage<\/td>\n<td>400\/415V AC<\/td>\n<\/tr>\n<tr>\n<td>Rated Insulation Voltage<\/td>\n<td>1000V<\/td>\n<\/tr>\n<tr>\n<td>Rated Impulse Withstand Voltage<\/td>\n<td>8kV<\/td>\n<\/tr>\n<tr>\n<td>Rated Breaking Capacity<\/td>\n<td>35kA at 400V<\/td>\n<\/tr>\n<tr>\n<td>Service Breaking Capacity (Ics)<\/td>\n<td>35kA at 400V<\/td>\n<\/tr>\n<tr>\n<td>Network Type<\/td>\n<td>AC<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u062f\u062f<\/td>\n<td>50\/60 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td>Suitable for Isolation<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Connection Capacity<\/td>\n<td>70 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Utilisation Category<\/td>\n<td>Category A<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/td>\n<td>1,500 Cycles<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/td>\n<td>8,500 Cycles<\/td>\n<\/tr>\n<tr>\n<td>Protection Degree<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Dimensions (H \u00d7 W \u00d7 D)<\/td>\n<td>155 \u00d7 90 \u00d7 108 mm<\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature<\/td>\n<td>-5\u00b0C to +40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Storage Temperature<\/td>\n<td>-20\u00b0C to +70\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Operating Altitude<\/td>\n<td>0\u20132000 m<\/td>\n<\/tr>\n<tr>\n<td>Installation Category<\/td>\n<td>III<\/td>\n<\/tr>\n<tr>\n<td>Pollution Degree<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0645\u0639\u064a\u0627\u0631<\/td>\n<td>IEC 60947-2<\/td>\n<\/tr>\n<tr>\n<td>Certification<\/td>\n<td>T\u00dcV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\nFor more information about HIMEL electrical products, visit the official website:<br \/>\n<a href=\"https:\/\/www.himel.com\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/www.himel.com<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p data-start=\"146\" data-end=\"545\">The HIMEL HDM3S160M04031XX Molded Case Circuit Breaker (MCCB) delivers dependable overload and short-circuit protection for AC power distribution systems. Featuring a thermal-magnetic trip unit, a 40A current rating, 35kA breaking capacity, and a 3-pole configuration, it provides reliable protection for industrial and commercial electrical installations while complying with IEC 60947-2 standards.<\/p>","protected":false},"featured_media":2573,"comment_status":"open","ping_status":"closed","template":"","meta":{"pagelayer_contact_templates":[],"_pagelayer_content":"","advanced_seo_description":"","jetpack_seo_html_title":"","jetpack_seo_noindex":false,"jetpack_seo_schema_type":""},"product_brand":[36],"product_cat":[58],"product_tag":[505,517,506,540,525,539,45,337,336,503,504,537,510],"class_list":["post-2569","product","type-product","status-publish","has-post-thumbnail","product_brand-himel","product_cat-molded-case-circuit-breakers-mccb","product_tag-3-pole-mccb","product_tag-35ka-mccb","product_tag-3p-mccb","product_tag-40a-mccb","product_tag-hdm3s","product_tag-hdm3s160m04031xx","product_tag-himel","product_tag-iec-60947-2","product_tag-industrial-circuit-breaker","product_tag-mccb","product_tag-molded-case-circuit-breaker","product_tag-power-distribution-protection","product_tag-thermal-magnetic-mccb","first","instock","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product\/2569","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/comments?post=2569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/media\/2573"}],"wp:attachment":[{"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/media?parent=2569"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product_brand?post=2569"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product_cat?post=2569"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/wordpress.gfmegypt.com\/ar\/wp-json\/wp\/v2\/product_tag?post=2569"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}