Description

Reliable Thermal-Magnetic Protection for Industrial and Commercial Power Distribution
The HIMEL Molded Case Circuit Breaker (MCCB) 3P 32A 35kA Thermal-Magnetic HDM3S160M03231XX is designed to provide dependable protection against overloads and short circuits in low-voltage AC power distribution systems. Built with a thermal-magnetic trip unit, it delivers consistent performance while ensuring safe operation of electrical installations.
HIMEL Molded Case Circuit Breaker (MCCB) 3P 32A 35kA Thermal-Magnetic HDM3S160M03231XX
Designed for reliable circuit protection, this HIMEL MCCB combines a 32A current rating with a 35kA breaking capacity, making it suitable for a wide range of industrial and commercial electrical applications. Its enclosed molded case construction enhances durability while maintaining safe operation under demanding conditions.
The breaker supports AC networks operating at 400/415V and 50/60Hz. It features a 3-pole configuration, thermal-magnetic trip technology, and isolation capability. Manufactured in accordance with IEC 60947-2 standards, it also provides excellent electrical and mechanical durability for long-term service.
HIMEL Molded Case Circuit Breaker (MCCB) 3P 32A 35kA Thermal-Magnetic HDM3S160M03231XX Key Features
- Brand: HIMEL
- Product Type: Molded Case Circuit Breaker (MCCB)
- Model: HDM3S160M03231XX
- Series: HDM3S
- Frame Size: 160AF
- Current Rating: 32A
- Pole Configuration: 3P
- Breaking Capacity: 35kA at 400V
- Service Breaking Capacity (Ics): 35kA at 400V
- Trip Unit Technology: Thermal-Magnetic
- Rated Operational Voltage: 400/415V AC
- Rated Insulation Voltage: 1000V
- Impulse Withstand Voltage: 8kV
- Frequency: 50/60Hz
- Suitable for Isolation: Yes
- Application: Power Distribution Protection
- Electrical Durability: 1,500 Cycles
- Mechanical Durability: 8,500 Cycles
- Protection Degree: IP20
- Standard: IEC 60947-2
- Certification: TÜV
HIMEL MCCB 3P 32A HDM3S160M03231XX Applications
- Industrial power distribution systems
- Commercial electrical panels
- Main distribution boards
- Motor and feeder protection
- Manufacturing facilities
- Infrastructure projects
- Building electrical installations
- Low-voltage switchboards
HIMEL MCCB 3P 32A 35kA HDM3S160M03231XX Technical Specifications
| Specification | Value |
|---|---|
| Brand | HIMEL |
| Series | HDM3S |
| Model | HDM3S160M03231XX |
| Product Type | Enclosed Molded Case Circuit Breaker (MCCB) |
| Frame Size | 160AF |
| Current Rating | 32A |
| Poles | 3P |
| Trip Unit Technology | Thermal-Magnetic |
| Rated Operational Voltage | 400/415V AC |
| Rated Insulation Voltage | 1000V |
| Rated Impulse Withstand Voltage | 8kV |
| Breaking Capacity | 35kA at 400V |
| Service Breaking Capacity (Ics) | 35kA at 400V |
| Frequency | 50/60Hz |
| Network Type | AC |
| Isolation | Yes |
| Application | Power Distribution Protection |
| Electrical Durability | 1500 Cycles |
| Mechanical Durability | 8500 Cycles |
| Connection Capacity | 70 mm² |
| Utilisation Category | Category A |
| IP Rating | IP20 |
| Dimensions (H × W × D) | 155 × 90 × 108 mm |
| Operating Temperature | -5°C to +40°C |
| Storage Temperature | -20°C to +70°C |
| Operating Altitude | 0–2000 m |
| Installation Category | III |
| Pollution Degree | 3 |
| Standard | IEC 60947-2 |
| Certification | TÜV |
HIMEL MCCB HDM3S160M03231XX FAQ
Q: What is the rated current of this MCCB?
A: The breaker has a rated current of 32A.
Q: What is the breaking capacity?
A: It provides a rated breaking capacity of 35kA at 400V.
Q: Which trip unit technology does it use?
A: It uses a Thermal-Magnetic trip unit.
Q: Is this breaker suitable for isolation?
A: Yes, it is suitable for isolation.
Q: Which standard does this MCCB comply with?
A: It complies with IEC 60947-2.